LDC-2/2.2-6dB-S 2 In 4 Out Hybrid Coupler
Type:LDC-2/2.2-6dB-S
Frequency:2-2.2Ghz
Insertion Loss:0.6dB
Amplitude Balance:±0.35dB
Phase Balance: ±5
VSWR: ≤1.25: 1
Isolation:≥20dB
Connecter:SMA-F
Power:10W
Operating Temperature Range:-20˚C ~+65˚C
Outline:Unit: mm
-
LDC-2/18-180S 2-18Ghz 180 Degree Hybrid splitter coupler
Type:LDC-2/18-180S Frequency:2-18Ghz
Insertion Loss:2.0dB Amplitude Balance:±0.6dB
Phase Balance: ±10 VSWR: ≤1.6: 1
Isolation:≥16dB Connecter:SMA-F
Power: 20W Operating Temperature :-40˚C ~+85˚C
-
LDC-4/10-90N Hybrid Combiner With Low phase and amplitude unbalance
Type:LDC-4/10-90N
Frequency:4-10Ghz
Insertion Loss:1.0dB
Amplitude Balance:±0.7dB
Phase Balance: ±4
VSWR: ≤1.4: 1
Isolation:≥17dB
Connecter:N-F
Power: 50W
Operating Temperature Range:-40˚C ~+85˚C
Outline:Unit: mm
-
LDC-5/50-90S 50Ghz 90degree hybrid combiner
Type:LDC-5/50-90S Frequency:5-50Ghz
Insertion Loss:2.8dB Amplitude Balance:±1.4dB
Phase Balance: ±10 VSWR: ≤2.1: 1
Isolation:≥11dB Connecter:2.4-F
Power: 5W Impedance:50 OHMS
Operating Temperature Range:-40˚C ~+85˚C
-
LDC-6/18-90S 90 degree hybrid combiner with SMA connecter
Type:LDC-6/18-90S Frequency:6-18Ghz
Insertion Loss:0.75dB Amplitude Balance:±1dB
Phase Balance: ±5 VSWR: ≤1.6: 1
Isolation:≥15dB Connecter:SMA-F
-
LDC-6/26.5-180S 6-26.5Ghz 180° Hybrid Coupler Combiner
Type:LDC-6/26.5-180S Frequency:6-26.5Ghz
Insertion Loss:2.2dB Amplitude Balance:±0.8dB
Phase Balance: ±10 VSWR: ≤1.7: 1
Isolation:≥14dB Connecter:SMA-F
Power: 50W Operating Temperature:-40˚C ~+85˚C
-
LDC-7/12.4-180S 7-12.4Ghz 180° Hybrid Coupler combiner
Type:LDC-7/12.4-180S
Frequency:7-12.4Ghz
Insertion Loss:1.0dB
Amplitude Balance:±0.4dB
Phase Balance: ±5
VSWR: ≤1.45: 1
Isolation:≥18dB
Connecter:SMA-F
Power: 50W
Operating Temperature Range:-40˚C ~+85˚C
Outline:Unit: mm
-
LDC-7.2/8.5-180S 7.2-8.5Ghz 180° Hybrid Coupler combiner
Type:LDC-7.2/8.5-180S
Frequency:7.2-8.5Ghz
Insertion Loss:0.65dB
Amplitude Balance:±0.6dB
Phase Balance: ±4
VSWR: ≤1.45: 1
Isolation:≥18dB
Connecter:SMA-F
Power: 20W
Operating Temperature Range:-40˚C ~+85˚C
Outline:Unit: mm
-
LDC-12/18-180S 12-18Ghz 180° Hybrid Coupler
Type:LDC-12/18-180S
Frequency:12-18Ghz
Insertion Loss:1.8dB
Amplitude Balance:±0.8dB
Phase Balance: ±5
VSWR: ≤1.5: 1
Isolation:≥15dB
Connecter:SMA-F
Power: 50W
Operating Temperature Range:-40˚C ~+85˚C
Outline:Unit: mm
-
LDC-18/40-90S 18-40Ghz 90degree hybrid coupler
Type:LDC-18/40-90S Frequency:18-40Ghz
Insertion Loss:2.0dB Amplitude Balance:±1dB
Phase Balance: ±10 VSWR: ≤1.6: 1
Isolation:≥14dB Connecter:2.92-F
Power: 10W Impedance:50 OHMS
Operating Temperature Range:-40˚C ~+85˚C
-
4×4 LDQ-0.698/3.8-N 4X4 Hybrid Coupler
Type:4×4 LDQ-698/3800-N
Frequency:698-3800Mhz
Insertion Loss:7.2dB
Amplitude Balance:±0.6dB
Phase Balance: ±5
VSWR: ≤1.30: 1
Isolation:≥20dB
Connecter:N-F or 4.3-10
PIM(IM3):<-150dBc@2×+43dBm
Power: 300W
Operating Temperature Range:-40˚C ~+85˚C
Outline:Unit: mm
-
700-2700Mhz 3dB Hybrid Coupler
Type:LDQ-0.7/2.7-3dB-3NA Frequency:0.7-2.7Ghz
Insertion Loss:3dB Amplitude Balance:±0.6dB
VSWR: ≤1.3: 1 Isolation:≥20dB
Power: 200W PIM 3:≤-150dBc @(+43dBm×2)
Connecter:N-F Operating Temperature Range:-40˚C ~+85˚C